Firefighting and Disaster Prevention Equipment

About Icons

  • Eco Mark (Type I)
  • Self-Declared Type (Type II)
  • RoHS Directive
  • PFOS (Chemical Substances Control Law)
  • CUD Mark

Rescue EquipmentRescue Equipment

Features

Rescue device for emergency situation
After natural disasters such as typhoons and earthquakes, rescuers face many challenges. Pat Jack has been developed after many experiments to solve one of the greatest challenges, that of raising masonry or building materials to free victims of the disaster. The Pat Jack is perfect for emergency situations, light weight, portable, simple inflation and most importantly it is safe.

1. Can be inflated using bicycle pomp
2. Light weight
3. Thickness 19 mm
4. Flexibility
5. Safety

Conditions of Use for PatJack SA/SB

Maximum Operating Pressure:
0.7 Mpa (SA type) , 0.3 MPa (SB type)
Operating Temperature Range:
-10°C to 60°C
Fill with air only
Fill with bicycle pump, or air compressor (SA type only)

Specifications

Product Name

PatJack SA Type

Features For rescue
Air Filling Method Air compressor or bicycle pump
Model SA24-30 SA24-60 SA24-90
Length 365
mm
625
mm
925
mm
Width 240 mm
Thickness 19 mm
Weight 0.8 kg 1.1 kg 1.6 kg
Maximum Load 4,000
kg
8,000
kg
12,000
kg
Maximum Lifting Height 140 mm
Maximum Operating Pressure 0.7 MPa
Safety Valve Actuation Pressure 0.8 MPa
Conditions of Use Fill with air only
Operating temperature range:
-10°C to 60°C
Product Name

PatJack SB Type

Features For rescue
Air Filling Method Bicycle pump only
Model SB24-30 SB24-60 SB24-90
Length 365
mm
625
mm
925
mm
Width 240 mm
Thickness 19 mm
Weight 0.7 kg 1.0 kg 1.5 kg
Maximum Load 1,700
kg
3,400
kg
5,100
kg
Maximum Lifting Height 140 mm
Maximum Operating Pressure 0.3 MPa
Safety Valve Actuation Pressure 0.4 MPa
Conditions of Use Fill with air only
Operating temperature range:
-10°C to 60°C